CDTGJ - IGNITER, 103377-3

  • MSDS: CDTGJ
  • Manufacturer: SPECIAL DEVICES INC
  • Product Name: IGNITER, 103377-3
  • National Stock Number: 1377-00N049054
Product Identification

Product ID:IGNITER, 103377-3
MSDS Date:09/05/1995
FSC:1377
NIIN:00N049054
MSDS Number: CDTGJ

Responsible Party
SPECIAL DEVICES INC
16830 WEST PLACERITA CANYON RD
NEWHALL, CA 91321
US

Emergency Phone: 800-255-3824

Info Phone: 805-259-0753

Cage: 14720

Contractor
SPECIAL DEVICES, INC.
NEWHALL, CA 91321

Telephone: (805) 259-0753

Cage: 14720

Ingredients

INITIATING MATERIAL, CONTAINING INGREDIENTS 2 AND 3

RTECS: 9999999ZZ

Fraction By Weight: 65% MG

OSHA PEL N/K

ACGIH TLV: N/K


ZIRCONIUM

CAS: 7440-67-7

RTECS: ZH7070000

Fraction By Weight: 50%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3/10 STEL


PERCHLORIC ACID, POTASSIUM SALT; (POTASSIUM PERCHLORATE)

CAS: 7778-74-7

RTECS: SC9700000

Fraction By Weight: 50%

OSHA PEL N/K

ACGIH TLV: N/K


PRESSURE COMPOSITION, CONTAINING INGREDIENTS 5 AND 6

RTECS: 9999999ZZ

Fraction By Weight: 117% MG

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM HYDRIDE

CAS: 7704-98-5

RTECS: XR2110000

Fraction By Weight: 50%

OSHA PEL N/K

ACGIH TLV: N/K


PERCHLORIC ACID, POTASSIUM SALT; (POTASSIUM PERCHLORATE)

CAS: 7778-74-7

RTECS: SC9700000

Fraction By Weight: 50%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: NOT APPLICABLE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NOT APPLICABLE.

First Aid

First Aid:INHALATION: NOT APPLICABLE. REMOVE TO FRESH AIR. SUPPORT
BREATHING (GIVE OXYGEN OR ARTIFICIAL RESPIRATION) . EYES/SKIN: USE
SUFFICIENT PERSONAL PROTECTIVE EQUIPMENT TO PREVENT INJURY FROM
SHRAPN EL WHEN UNIT IS UN-CONTAINED. FLUSH EYES W/POTABLE WATER FOR
AT LEAST 15 MINUTES. SEE MD . FLUSH SKIN W/COPIOUS AMOUNTS OF
WATER. SEE MD . INGESTION: NOT APPLICABLE. CALL MD IMMED .

Fire Fighting

Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EXPLOSIVE FORMULATION (SEE INGREDIENTS)
MAY EXPLODE OR IGNITE WHEN EXPOSED TO FIRE.

Accidental Release

Spill Release Procedures:USE PPE AND GROUNDING STRAP TO PREVENT
DISCHARGE OF ACCUMULATED ELECTROSTATIC CHARGES TO THE UNIT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:IGNITER. HAZARD CLASS AND
COMPATIBILITY GROUP: 1.4 S. UN NUMBER: UN0454.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT APPLICABLE. USE NIOSH APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . FLAME RETARDANT SHOP COATS AND BODY
SHIELDING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
APPEAR/ODOR: HERMETICALLY SEALED CLOSURE. NO ODOR.

Chemical Properties

Appearance and Odor:STAINLESS STEEL BODY WITH STANDARD MS CONNECTOR AND
THREATED OUTPUT. (SUP DAT)

Stability

Stability Indicator/Materials to Avoid:YES
UNKNOWN. HANDLE CAREFULLY. KEEP FIRE AWAY.
Stability Condition to Avoid:TEMPERATURES IN EXCESS OF 600F.
Hazardous Decomposition Products:NOT APPLICABLE.

Disposal

Waste Disposal Methods:INITIATE BY APPLICATION OF 5 AMPERS OF CURRENT
TO THE BRIDGEWIRE CIRCUIT. UNIT SHOULD BE CONTAINED TO PREVENT
HAZARDS OF SHRAPNEL. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS (F P N).

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.